SkyWay–LM
Licensed Microwave Point-to-Point Link
Specifications
System
Frequency Bands 6 – 40 GHz
Modulation mode QPSK, 16QAM, 32QAM, 64QAM, 128QAM
Channel Bandwidth
CEPT/ETSI 7, 14, and 28 MHz
ANSI/FCC 10, 20, and 30 MHz
Data Rate 2 – 160 Mbps
Output Power up to 30 dBm
RX Sensitivity at BER = 10-8
QPSK -72 dBm
QAM16 -68 dBm
QAM32 -66 dBm
QAM64 -64 dBm
QAM128 -61 dBm
IF Frequencies 350 MHz (Tx) and 140 MHz (Rx)
Forward Error Correction
Configurable Reed-Solomon coding
Configurable interleaving frame length
End-to-End Latency less than 250 microseconds.
Link Quality Metrics ITU-T G.826 support
Power Supply -20 to -60 VDC to IDU (ODU powered by IF Cable).
Power Consumption 60W, typical
MTBF 32 years
Compliance FCC part 101, ETSI EN 302 217-2-2
Outdoor Unit (ODU)
Configuration Direct Mount
Size 10.5 in. (26.7 cm) in diameter, 3.5 in. (8.9 cm) in height
Weight 10.1 lbs. (4.6 kg)
Temperature -33ºC to 55ºC
Indoor Unit (IDU)
Configuration 1U 19" Rack Mount
Size (H x D x W) 1.7 x 14 x 17 in. (4.3 x 35.6 x 43.2 cm)
Weight 9 lbs. (4.1 kg)
Temperature 0º to 40ºC
Interface
IDU Data Interfaces (4) 100 Base-T and up to 16 T1/E1
IDU/ODU interface (2) N-type connector (female)
IF Cable (2) 50-Ohm coax cable
LEDs Power, Alarm, Fault
Management  
Ethernet SNMP, Web Management
RS232 Command Line Interface